What is a radiant warmer NICU?

What is a radiant warmer NICU?

Example of radiant warmer

Standards may be international or local national (by country). The IEC standards reflect the best experience of the industry, researchers, consumers, and regulators worldwide. They help establish a uniform and universal testing procedure for biomedical, service, and design engineers to use, and are critical in helping properly assess the safety of medical devices and ensuring patient safety. For this reason, most of the local national (by country) standards have been harmonized to the IEC standards, which are recognized as the international preferred practice. The IEC 60601-2-19, 60601-2-20, and 60601-2-21 standards recommend basic safety and essential performance requirements for infant incubator, transport incubator, and radiant warmer testing.

While voluntary, most manufacturers recognize that the customers in the markets they service will hold them accountable to these standards and will thus base their testing procedures around them. A manufacturer’s service manual will contain procedures specific to the maintenance and performance of the device, and typically recommend an inspection frequency. While these testing workflows tend to not to be quite as thorough as the standards, each manufacturer applies the standards to the best testing for the design of their brand and model of infant incubator, transport incubator, or radiant warmer.

The manufacturer’s manual will give model-specific directions to test the incubator or radiant warmer, such as the need to ensure warning lights turn on when they should (i.e. if the temperature is too high, the alarm should sound). Complete the performance inspection per the standards and/or manufacturer’s procedures.

2. Adopt a consistent inspection frequency

An infant’s first few days of life can be their most critical, which is why it’s important to routinely test and verify the safety and performance of infant incubators and radiant warmers. Check the manufacturer’s service manual for frequency recommendations; most manufacturers recommend a minimum inspection frequency of once per year.

If the service manual and inspection procedure from the manufacturer is not available, the frequency of inspection must still be determined. One method for determining how often a medical device should be tested is a risk-based method used by the University of Vermont Biomedical Engineering Department. As shown in the table below, this method is described in Medical Equipment Quality Assurance: Inspection Program and Development Procedures by J. Tobey Clark.

You are here

Edward F. Bell, MD
Peer Review Status: Internally Peer Reviewed

Radiant warmer to incubator:

Most newly-admitted infants are cared for on radiant warmer beds in order to provide accessibility for resuscitation or procedures without jeopardizing thermal stability. As long as an infant remains critically ill and is likely to require resuscitation or frequent procedures, he should be kept on a warmer bed. Most very small infants (<1000 grams) can be kept warm more easily on a radiant warmer than in an incubator, since incubator air temperature drops rapidly when the door is opened. If a very small infant has difficulty maintaining normal body temperature on a radiant warmer, plastic food wrap can be stretched across the bed (from side to side). This reduces the movement of cool air over the baby's body surface.

When the condition has stabilized so that frequent procedures are not likely to be needed, an infant can be moved to a preheated incubator, on skin temperature servocontrol. Axillary temperature should be checked 30 minutes after moving the baby to the incubator, and every hour thereafter for four hours. The very small infant is at greatest risk of heat loss through an open incubator door. Whenever possible, procedures performed on a baby in an incubator should be performed through the ports (diaper change, vital signs, phlebotomy, etc.). Any infant who weighs less than 1000 grams should be cared for on a radiant warmer or in a servocontrolled double-walled incubator. If an infant consistently requires an air temperature above 37° C, it may be necessary to operate the incubator in the air temperature control mode to avoid periodic increases in air temperature to above 38° C, which may cause the heater to stop completely. Some infants who require a radiant warmer for temperature support may not need routine vital signs as often as other infants under radiant warmers. The frequency of vital signs may be reduced at the discretion of the infant's nurse and physician.

Incubator to bassinet:

If an infant has been maintained in an incubator operated by skin temperature servocontrol, the incubator should be changed to air temperature servocontrol in the following manner, before attempting the move the infant to a bassinet.

  • Change to air temperature servocontrol setting the control temperature to equal the average incubator air temperature during the previous 24 hours (from the nursing notes).
  • Check the baby's axillary temperature in 30 minutes and each hour for four hours.
  • If the axillary temperature remains normal (36.5 to 37.4°C), disconnect and remove the skin probe if desired.

When an infant reaches 1700 to 1800 grams, has no respiratory distress and only occasional apnea, and has been stable in an incubator operated in the air temperature control mode with air temperature 32°C or less, an attempt can be made to move him to a bassinet as follows:

  • Dress the infant in shirt and diaper and wrap him in a single blanket. Turn the air temperature control to 28°C.
  • Check the baby's temperature in 30 minutes and each hour for four hours.
  • If the baby's axillary or rectal temperature drops to below 36.5°C, reheat him in the skin temperature servocontrol mode until his skin temperature is 36.0°C and return to manual or air servocontrol mode as described above (try again in two or three days).
  • If the baby's temperature is stable for eight hours, bundle him in extra blankets and move him to a bassinet.
  • Check body temperature in 30 minutes and each hour for four hours; if the axillary or rectal temperature drops to below 36.5°C, return infant to incubator, reheat on skin temperature servocontrol as described above, then revert to air temperature control; try again in two or three days.

Reference

Bell EF. Infant incubators and radiant warmers. Early Hum Dev 1983;8:351-375.

A bed for stabilizing the body temperature of a newborn or premature infant. It has a heat source positioned above the baby to keep his or her temperature constant. Unlike an incubator, it is not enclosed.

Medical Dictionary, © 2009 Farlex and Partners

Want to thank TFD for its existence? Tell a friend about us, add a link to this page, or visit the webmaster's page for free fun content.

Link to this page:

<a href="https://medical-dictionary.thefreedictionary.com/radiant+warmer">radiant warmer</a>

Most common equipment used in neonatal intensive care unit are bililights, central line, cardiopulmonary monitor, blood pressure monitor, incubator, oxygen hood, radiant warmer, ventilator, endotracheal tube, umbilical catheter, are some of the most common equipment used in infant care units in hospitals.

A question submitted to the FDA-sponsored MedSun newsletter summarized the issue: "We are using electrosurgical units (ESUs) with infants in radiant warmers and are concerned that the patient temperature probe used with the radiant warmer might provide an alternate path for the ESU's radio frequency energy and lead to a burn at the site of the temperature probe.


What is a radiant warmer NICU?


Neonatal warming system, radiant, overhead, mobile, with accessories

Product attributes

Optional Features:
Electrical Height Adjustment, In-Built Weighing Scale, Oxygen cylinder mounting provision, Flow meter, X-ray cassette tray

Accessories:

Skin Temperature ProbeBaby MattressX-Ray TrayOxygen HoodsHumidifier Bottle, Suction Bottle, Venturi Slow SuctionOxygen CylindersFlow Meters

IV Poles